Monitors wheel speed, engine speed and position of the engine.
Variable reluctance and active hall effect or magneto resistive sensors
Zero speed, large air gap capability
Packaged to resist harsh environments
Customizable options
● Ultrasonic Fluid Level Sensors
Continuously monitors liquid levels within tank or reservoir, including fuel, coolant and hydraulic fluids.
High accuracy
Robust, non-contact sensing
Slosh filtering
Customizable options
● Vibration Sensors
Continuously monitoring engine balance.
Early fault detection
Compact sensor placement
High sensitivity and extremely low noise
Suitable for temperatures from -400° F to +1400°F
● Pressure Sensors
Combustion instability measurement.
Fast repsonse time
High accuracy
Long-term stability and repeatability
Suitable for temperatures from -400° F to +1400°F
This will close in 0 seconds
Comm Aerospace - Wind Tunnel Testing
Wind Tunnel Testing Applications
● Pressure Sensors ● Accelerometers ● Microphones
Click on the logos to explore company sites.
● Pressure Sensors
Aerodynamic testing
Piezoresistive pressure sensors for static accuracy
Piezoelectric pressure sensors for turbulent and shock waves
● Accelerometers
Shock and vibration of wind tunnel models
● Microphones
Aero-acoustic testing
External surface noise on aircraft
This will close in 0 seconds
Comm Aerospace - Flight & Ground Testing
Flight & Ground Testing Applications
● Pressure Sensors ● Accelerometers ● Microphones
Click on the logos to explore company sites.
● Pressure Sensors
Aerodynamic testing
Piezoresistive pressure sensors for static accuracy
Piezoelectric pressure sensors for turbulent and shock waves
● Accelerometers
Shock and vibration of aircraft and helicopters
● Microphones
Aero-acoustic testing
External surface noise on aircraft
Cabin noise testing
This will close in 0 seconds
Electrification - Battery Pack
Flight & Battery Pack Applications
Consists of a cluster of individual batteries that serve as the primary fuel source of the vehicle, replacing hydrocarbon fuels used in conventional ICE automobiles.
● Temperature Sensors ● Current Sensors ● Accelerometers
Click on the logos to explore company sites.
● Temperature Sensors
Measure and monitor surface temperature of the many batteries within the battery cell, which is critical to preserving the chemistry of the battery.
Single point temperature sensors
Rigid and flexible types
Custom sensor packaging
● Current Sensors
Measure and monitor current flowing to and from battery.
Hall effect, open loop current sensor
Busbar or wire mounting
Analog ratiometric output, 1 and 2 channels
● Water Detection Sensors
Detects moisture leakage and feeds a signal to the Battery Management System.
510kΩ±3%
Operating temperature range: -40C to +85C
RoHS Compliance (Directive 2011/65/EU)
● Accelerometers
Mechanincally testing the battery pack.
Electrically isolated sensors
Wide frequency range
High sensitivty with low noise
This will close in 0 seconds
Electrification - Thermal Runaway
Thermal Runaway Applications
Occurs when battery cells exceed allowable operating temperature causing an explosion/fire, which then propagates, or spreads, to other cells within the battery pack.
● Temperature Sensors ● Pressure Sensors ● Gas Detection Sensors
Click on the logos to explore company sites.
● Temperature Sensors
Measure and monitor battery temperature to detect Thermal Runaway conditions.
Capable of single or multiple cell detection
● Pressure Sensors
Detect pressure change inside the battery cell that indicates Thermal Runaway conditions.
Surface mountable
Simple 3-command I2C interface
Very low current consumption: less than 35μA
● Gas Detection Sensors
Detect the out-gassing of Carbon Dioxide (CO2) to indicate pre-combustion conditions.
Single and dual channel configurations
Self-calibration with patented ABC LogicTM Software
● Gas Detection Sensors
Detect the presence of combustible gases that indicate Thermal Runaway conditions.
Sensitive to multiple gases: CO / H2 / NH3 / CO2
Temperature / Humidity sensor
Pressure sensor (20 up to 250 kPa)
Fast response time: less than 1 second
IP6K7 rating
This will close in 0 seconds
Electrification - Cell Connection System (CCS)
Cell Connection System (CCS) Applications
Used as top cover of the battery cell to provide connectivity with the Battery Management System (BMS).
● Temperature Sensors ● Current Sensors
Click on the logos to explore company sites.
● Temperature Sensors
Provide temperature and voltage sensing to monitor the state of charge of the battery cells.
High current circuit for battery cell connectivity
Available styles: Wire Harness and Flexible Printed Circuit (FPC)
● Current Sensors
Measure and monitor the state of charge of the battery cells.
Busbar, wire mounting, or integrated busbar
Analog ratiometric output
This will close in 0 seconds
Electrification - Power Inverter / E-Motor
Power Inverter / E-Motor Applications
Converts higher voltage DC electricity to lower voltage AC electricity that is required to power the electric motor.
● Temperature Sensors ● Inductive Position Sensors ● Current Sensors
Click on the logos to explore company sites.
● Temperature Sensors
Measure and monitor operating temperature of the power inverter to provide feedback on unsafe conditions.
Fast response time
Pigtail connector
● Inductive Position Sensors
Provide data on the angular position of the rotating motor shaft to optimize control of the motor inverter.
Compact and lightweight alternative to resolvers
Flexible integration in on-axis and off-axis configuration
Robust against magnetic flux and external stray fields
● Current Sensors
Measure and monitor current flowing to and from battery.
Hall effect, open loop current sensor
Busbar mounting, 1 phase and 3 phase housing
Analog ratiometric output
This will close in 0 seconds
Electrification - High Voltage Charger Connector
High Voltage Charger Connector Applications
Connects the high voltage source to charge the battery within the vehicle.
● Temperature Sensors
Click on the logos to explore company sites.
● Temperature Sensors
Detect over-temperature conditions during charging.
Installed within the connector
This will close in 0 seconds
Electrification - Motor Coil
Motor Coil Applications
Wire coils that generate a magnetic field and conduct electric current. The interaction between the two generates rotation of the motor shaft and the actual conversion of electrical to mechanical energy.
● Temperature Sensors
Click on the logos to explore company sites.
● Temperature Sensors
Measure and monitor temperature of the motor coil to provide feedback on the operating conditions of the electric motor.
Field-proven design
Variety of lead lengths, terminal and connector options
This will close in 0 seconds
Electrification - Battery Coolant
Battery Coolant Applications
Circulates around the battery cell to assist in maintaining optimum battery temperature.
Measure and monitor fluid temperature of inlet/outlet battery coolant to provide indication of battery cell temperature.
No leak path – Sensor cavity and tube are one piece
USCAR sealed connection system
Various part geometries available
● Coolant Breach / Water Intrusion Sensors
Detect the presence of coolant / water in the battery pack.
Operates based on conductivity of the fluid being sensed
Easy to install
RoHS compliant
● Pressure Sensors
Measure the pressure in the cooling system to control pump capacity.
Internal metal sealing for high media compatibility and no leakage
Customized calibration for high accuracy
● Combined Pressure & Temperature Sensors
Measure pressure in the cooling system, while, at the same time, measure temperature of the coolant for optimum thermal management.
Available versions: R1234yf (up to 35bar) and R744 (up to 200bar)
Tested LIN 2.1 conformity
Automatic address assignment within LIN network
● Ultrasonic Level & Temperature Sensors
Continuously monitor fluid level for early detection of coolant leakage.
Level accuracy: ±2mm
Temperature accuracy: ±2.5°C
Output protocol offerings: Analog, PWM, SENT, CAN, LIN
Input voltage options: 5V / 12V / 48V
This will close in 0 seconds
Electrification - Fuel Cell
Fuel Cell Applications
Typically generates electricity by combining atmospheric oxygen and on-board compressed hydrogen.
● Temperature Sensors ● Pressure Sensors ● Gas Detection Sensors ● Level Sensors
Click on the logos to explore company sites.
● Temperature Sensors
Monitor temperature in various areas of a fuel cell vehicle to enable safety and efficiency throughout the system, e.g., Battery, Fuel Cell, Cooling System, Transmission and Converter.
Moisture proof construction
Fast repsonse time
High temperature monitoring
● Gas Detection Sensors
Measure the concentration of H2 and humidity.
Sensitive to H2 gases
Temperature / Humidity sensor
Fast response time: less than 1 second
IP6K7 rating
● Water Level Sensors
Ultrasonic Switch indicates water level in the steam / water separation tank.
Single point ultrasonic switch
Microprocessor controlled analog output (voltage)
All-plastic design (PPS) eliminates opportunity for metal ionization
● Pressure Sensors
Robust sensors for fuel-cell applications, specifically designed to withstand the harsh conditions in hydrogen environments.
High accuracy and performance
Wide pressure range
Custom options
This will close in 0 seconds
HVOR - Fuel Handling System
Fuel Handling System Applications
●●●● Fuel ● EVAP
Click on the logos to explore company sites.
● Temperature Sensors
High accuracy
High stability
Integral/pigtail options
Combination sensor options
● Pressure Sensors
High accuracy
High performance
Long-term stability
Custom options
● Level Sensors
High accuracy
Continuous monitoring
Robust non-contacting sensors
Slosh and aeration filtering software
● Position Sensors
Absolute, non-contact measurement
Highest reliability
Robust and compact design for harsh environments
This will close in 0 seconds
HVOR - Cabin Comfort
Cabin Comfort Applications
● Discharge Air ● Steering Wheel ●● Seats ● Dewpoint ● Cabin Air Filter ● Particulate Detection ● Joystick Control ● Cabin Noise ● NVH ● Handle Throttle ● Toxic Gas Detection ● Cabin Suspension
Click on the logos to explore company sites.
● Temperature Sensors
High accuracy
High stability
Noise immune NTC option
Moisture resistant
Fast response time
● Pressure Sensors
High accuracy
High performance
Customizable design
Multiple output options
● Gas Detection Sensors
Detectable gases: CO2, CO, NO2, NH3
PWM and LIN bus
Custom packaging options
● Dewpoint Sensors
PWM and LIN Bus
Custom package options
Combined temperature and humidity measurement
● Dust Particulate Sensors
PM2.5
Laser detection
Fast response
High accuracy
● Position Sensors
Non-contact inductive and hall-effect technologies
Excellent resolution and precision
Reliable in harsh environments
Touch-less mechanical solutions
● Position Sensors
Absolute, non-contact measurement
Highest reliability
Robust and compact design for harsh environments
● Acoustic Sensors
Specialized microphones for a wide variety of applications
High temperature, water and dust resistant models available
Highly accurate
● Accelerometers
Wide frequency ranges available
Single and triaxial configurations
Robust design for demanding environments
Various mounting methods
Electrically isolated
High sensitivity and low noise
This will close in 0 seconds
HVOR - HVAC
HVAC Applications
● Outside Air ●●● Refrigerant/Coolant ● Evaporator ● Air Quality ● Particulate Detection ● HVAC Actuator
Click on the logos to explore company sites.
● Temperature Sensors
High accuracy
High stability
Noise immune NTC option
Moisture resistant
Fast response time
● Position Sensors
Robust and reliable modular design
Custom form-factor available
Selectable working principle: Potentiometric, hall effect, reed switch
Compatible with exhaust gas media and acid condensates
● DEF Level, Temperature & Concentration Sensors
High accuracy
Continuous monitoring
Meets EPA regulations
Programmable for irregular shape tank
This will close in 0 seconds
HVOR - Motion Control & Driver Assistant Systems
Motion Control & Driver Assistant Systems Applications
● Boom Arm Position / Extension ● Bucket / Tool Position ● Tilt Cylinder Control ● Hitch Position ● Telehandler Position ● Suspension Control ● Outrigger Position ● Load Management ● Automated Electro-hydraulic Steering
Click on the logos to explore company sites.
● Position Sensors
Absolute, non-contact measurement
Highest reliability
Robust and compact design for harsh environments
This will close in 0 seconds
HVACR - Air Handling Unit
Air Handling Unit Applications
Energy Efficiency
● Temperature Sensors ● Gas Sensors (CO2, Refrigerant) ● Humidity Sensors ● Pressure Sensors ● Position Sensors ● Vibration Sensors
Click on the logos to explore company sites.
● Temperature Sensors
Robust design for harsh environments
Thermal cut-off fuses for added safety
Customizations available
● Gas Sensors (CO2)
Lifetime calibration
Outputs: I2C, UART, BACnet and analog
Combination models with CO2, humidity and temperature
● Gas Sensors (Refrigerant)
Detectable gases: R290, NH3, R454, R32, R1234
Outputs: Linearized and analog voltage
500/1000 ppm to 100% LEL
● Humidity Sensors
Transmitters and OEM sensors
Field replaceable sensors
High IP rating protection
● Pressure Sensors
Types: Absolute, vented gauge and sealed gauge
Stainless steel, robust for harsh environments
Pressure range: 3psi – 7500psi
● Ultra Low Pressure Sensors
Air flow: monitoring and control
Pressure ranges: 0.25inch H2O to 150psi
Outputs: analog and digital
● Position Sensors
Flap motor positioning
High accuracy (2% linearity)
Low-cost and long life
● Vibration Sensors
Condition monitoring for fault detection of fans and motors